Dual SLC Panel Module-S758

The Dual Loop Panel Module monitors loop device status and provides status to the panel processor.
It holds device configurations and operates in a standalone manner when catastrophic failures occur.
The Dual Loop Panel Modules can be connected in any available slot (C-K) on the Main Back Board to provide this operating function.
Each Dual Loop Panel Module can support either Hochiki or Apollo protocols.

  Datasheet

Media Gateway Panel Module - S788

The Media Gateway™ is a communication panel module for the L@titude Fire Alarm Control Panel. The Media Gateway Panel Module provides connectivity to a remote monitoring center via Sur-Gard Fibro or dial-up. SIA is the recommended format for usage, but Contact ID is also supported. Transmission can be made through one or two telephone lines, and/or IP through Ethernet. Standard reporting codes have been pre-defined, although the user may customize these codes through the Loop Explorer 2 programming application. The Media Gateway can provide connectivity to third-party networks.

  Datasheet

8 Relay Panel Module - S791

The 8 Channel Relay Panel Module has 8 voltage-free changeover relay contacts, each of which can be individually programmed. All outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic. These boards are typically used in applications which require more than the five standard relay outputs, such as signalling to other systems or plant control.

  Datasheet

Network Card - 5723

The L@titude Network module provides enhanced high-Speed communication for networking up to a maximum of 127 fire control panels / annunciators.
L@titude Fire Alarm control panel and annunciators can receive events from other panels in the network. The Class X networking used in conjunction with the L@titude network module provides tolerance against open and short circuit troubles.

  Datasheet

16 Channel I/O Panel Module - S772

The 16 Channel I/O Interface enhances the versatility of the alarm system by providing additional input and output capabilities to the L@titude Fire Alarm Control Panel. Inputs or outputs can be selected up to 16 individual channels. All inputs and outputs are configured in the same way as devices connected to addressable loops of the panel. The 16 Channel I/O Interface can be configured to contribute or act upon cause and effect logic. Input points of this device are not supervised and therefore shall not be used for life safety initiation within a UL listed system. In a UL application this module must be housed in the panel or a listed enclosure connected to the panel by metal conduit. Power must also be provided by a UL listed power supply.

  Datasheet

4 NAC Panel Module - S793

NAC output capability can be added using 4 Channel NAC panel modules. These modules have 4 supervised NAC outputs, each individually programmed. Panel defined synchronization patterns are supported. Synchronization to other NAC outputs is also supported. All Channels may be configured in a Cause and Effect.

  Datasheet

FN-4127-IO - 16 CHANNEL INPUT/OUTPUT BOARD

The FireNET FN-4127-IO is a 16 channel Input/Output board that provides powerful input/output expansion & addition to the FireNET system allowing up to thirty two I/O boards to be connected to each FireNET panel within the FireNET network. Every I/O board connected to any panel is available to the entire network, which allows for network wide input/output mapping. Typical uses include graphical LED map displays /annunciators, tabular LED zone display/annunciators, input/output logic to & from the fire system for secondary use (I/O board points cannot be used for primary fire initiation inputs or notification outputs) such as access control, burglar, CCTV, intercom, voice, or other 3rd party systems. Each channel can be configured to produce a variety of input actions or respond to a variety of output categories or logic.